fix BME680 readings
This commit is contained in:
parent
e100978355
commit
a62b35cc18
|
|
@ -178,18 +178,27 @@ namespace BME_Utils {
|
|||
|
||||
uint32_t lastReading = millis() - bmeLastReading;
|
||||
if (lastReading > 60*1000) {
|
||||
#if defined(BME280Sensor) || defined(BMP280Sensor)
|
||||
bme.takeForcedMeasurement();
|
||||
newTemp = bme.readTemperature();
|
||||
newPress = (bme.readPressure() / 100.0F);
|
||||
#if defined(BME280Sensor) || defined(BME680Sensor)
|
||||
#ifdef BME280Sensor
|
||||
newHum = bme.readHumidity();
|
||||
#endif
|
||||
#ifdef BMP280Sensor
|
||||
newHum = 0;
|
||||
#endif
|
||||
|
||||
#endif
|
||||
|
||||
#ifdef BME680Sensor
|
||||
newGas = bme.gas_resistance / 1000.0; // in Kilo ohms
|
||||
bme.performReading();
|
||||
delay(50);
|
||||
if (bme.endReading()) {
|
||||
newTemp = bme.temperature;
|
||||
newPress = (bme.pressure / 100.0F);
|
||||
newHum = bme.humidity;
|
||||
newGas = bme.gas_resistance / 1000.0; // in Kilo ohms
|
||||
}
|
||||
#endif
|
||||
bmeLastReading = millis();
|
||||
}
|
||||
|
|
|
|||